Description
The meter has RS485 remote reading function and the following optional functions (blue backlight, to display power failure, total power, current, voltage, power, power factor, frequency, etc.) and can accurately measure active energy. The energy meter has a large screen LCD screen.
The single-phase two-wire din-rail energy meter also has a pulse output independent of the internal circuit. The port 21 of the meter is connected to the positive pole, and the port 20 is connected to the negative pole. The port 23 is the positive pole of RS485, and the port 24 is the negative pole of RS485. The circuit requires a voltage of 5~27V DC and a maximum current of 27 mA DC.
1.9.4 RS485 Communication Meter Reading Application (Communication Protocol) and Register Address
The meter can remotely record data such as electric energy in the meter through his RS485 interface and transcribe the electric energy data in the meter at close range with the handheld computer through its infrared communication interfac. The encoding format, parity (even parity) and data transmission mode (eight data bits, one stop bit) meet the MODBUS-RTU standard requirements. The communication baud rate can be 1200bps, 2400bps, 4800bps or 9600bps (default). If there is no special requirement, the meter is set according to the default baud rate of 9600bps. The meter address and communication baud rate can be modified by the software we provide.
1Data Format:
Address + Function Code +Data +CRC Check code
2Register Type
The meter uses two types of registers, independently addressed.
The first type is the data register, read-only, using command code 0x04 to read.
The second type is the parameter register, which is readable and writable, read using command code 0x03, and set using command code 0x10.
3Data Format
Float type dataThe data read from the meter conforms to the IEEE-754 standard floating-point number, and the data format is a 32-bit 4-byte single-precision floating-point data format
4.Data Register List
Data Register Address | Register Description | ||||
High Byte | Low Byte | Description | Unit | Format | Mode |
0 | 0 | Voltage | V | floating-point | read only |
0 | 8 | Current | A | floating-point | read only |
0 | 12 | Active Power | Kw | floating-point | read only |
0 | 1A | Reactive Power | Var | floating-point | read only |
0 | 2A | Power Factor | floating-point | read only | |
0 | 36 | Frequency | Hz | floating-point | read only |
1 | 0 | Total Active Power | Kwh | floating-point | read only |
4 | 0 | Total Reactive Power | Kvarh | floating-point | read only |
5.Parameter Register List
Parameterregister address |
RegisterDescription |
|||
HighByte |
LowByte |
Description |
Format |
Mode |
00 |
00 |
Baudrate (1200 2400 4800 9600) |
floating-point |
read,wright |
00 |
02 |
Checkdigit (0: even 1: odd 2: none) |
floating-point |
read,wright |
00 |
08 |
Communicationaddress (meter number 1-247) |
floating-point |
read,wright |
00 |
10 |
Relaycontrol (1: switch on 2: switch out) |
floating-point |
read,wright |
Specification
A: Front panel B: Cover C:Bottom D: Seal |
||
Front panel Flame-retardant PC Cover Flame-retardant ABSor PC Bottom Flame-retardant ABSor PC Dimension89.9mmx35mmX72mm Weight0.12Kg (Net Weight) | ||
|
Terminal |
Notice |
1/3 |
Input/output |
|
4/5 |
RS485 port |
|
6/7 |
Pulseoutput |
|
8/9 |
Neutral line |
1MODULES(Note:This model have not set button)
|
A: Front panel B: Cover C:Bottom D: Seal |
|
Front panel Flame-retardant PC Cover Flame-retardant ABSor PC Bottom Flame-retardant ABSor PC Dimension100mmx35mmX65mm Weight0.2 Kg (Net Weight) | ||
|
Terminal |
Notice |
1/2 |
Input/output |
|
3/4 |
||
20/21 |
Pulseoutput |
|
23/24 |
RS485 port |
2 MODULES
A: Front panel B: Cover C:Bottom D: Seal |
||
Front panel Flame-retardant PC Cover Flame-retardant ABSor PC Bottom Flame-retardant ABSor PC Dimension100mmx76mmX65mm Weight0.35Kg (Net Weight) | ||
|
Terminal |
Notice |
L1/L1 |
Input/output |
|
N/N |
Input/output |
|
1/2 |
Pulseoutput |
|
3/4 |
RS485 port |
Quick Detail
AC1A, 5A Current rating,126*97mm Dimensions , 40~60Hz frequency WithMODRUS-RTU protocol Internal Power Consumption is ≤2W / 10VA ,International standard IEC 62053-21,Operating Voltage is 181/279V AC (3~)
Applications
din rail energy meter modbus |
din rail energy meter |
din rail mounted energy meter |
din rail mounted energy meter india |
abb din rail energy meter |
single phase din rail energy meter |
Competitive Advantage
The meter can remotely record data such as electric energy in the meter through his RS485 interface and transcribe the electric energy data in the meter at close range with the handheld computer through its infrared communication interfac. The encoding format, parity (even parity) and data transmission mode (eight data bits, one stop bit) meet the MODBUS-RTU standard requirements. The communication baud rate can be 1200bps, 2400bps, 4800bps or 9600bps (default). If there is no special requirement, the meter is set according to the default baud rate of 9600bps. The meter address and communication baud rate can be modified by the software we provide.